Star Micronics LC-200 Printer User Manual


 
Set horizontaltab stops
Mode] ASCII Decimal Hexadecimal
Both I cESC> “D” nl
d ... cO>
I 2766 nl n2 ... 0 I IB 44nl n2 ... 00
Cancelsall currenthorizontaltab stopsand sets new tab stops at
columnsnl, n2,etc.inthecurrentcharacterpitch(picapitchifpro-
portional spacing is currently selected),where nl, n2, etc. are
numbersbetween1 and255.The maximumnumberof horizontal
tabstopsallowedis32in Standardmodeand64in IBMmode.The
tab stops must be specifiedin ascendingorder; any violationof
ascendingorderterminatesthetabstoplist.Standardterminationis
bythe<0>controlcode.To clearalltab stops,specify<ESC>“D”
<0>.
Set horizontaltab stopsevery n columns
Mode ASCII Decimal
Hexadecimal
std.
<ESC> “e” “O” n 27101
48 n
IB 65 30 n
<ESC>“e” <O> n 27101 0 n
IB 65 00 n
Cancelsallcurrenthorizontaltabstopsandsetsnewtabstopsevery
n columns,wheren is between1 and 127.
Resetall tab stops
Mode ASCII Decimal
Hexadecimal
lwl’1
<ESC> “R” 27 82
IB 52
Resetsthehorizontaltab stopsto theirpower-upvaluesin whicha
tab stopis setevery 8 columnstartingat column9. Also clearsall
verticaltab stops.
Horizontaltab
Mode
ASCII
Decimal
Hexadecimal
Both
<m>
9
09
Movestheprintpositionto thenexthorizontaltab stop.Ignoredif
thereisnonexthorizontaltabstopinthecurrentline.Notethatwhen
underliningis selected,spacesskippedbyhorizontaltabulationare
not underlined.