102 Avaya CMS Sun Fire V880/V890 Installation, Maintenance, and Troubleshooting May 2006
11. Using your thumb and forefinger, push the drive latch upward to release the drive handle.
Swing the handle away from the drive until you feel the drive connector disengage from
the backplane. Do not use excessive force. See the following figure.
12. Holding the drive by the handle, carefully slide it out of the drive bay.
13. Place the drive on an antistatic mat or in an antistatic bag.
14. Press Enter.
A message similar to the following is displayed:
Drive in Box Name "FCloop" slot 3
Logical Nodes being removed under /dev/dsk/ and /dev/rdsk:
Logical Nodes being removed under /dev/dsk/ and /dev/rdsk:
c1t3d0s0
c1t3d0s1
c1t3d0s2
c1t3d0s3
c1t3d0s4
c1t3d0s5
c1t3d0s6
c1t3d0s7