22 Avaya CMS Sun Fire V880/V890 Installation, Maintenance, and Troubleshooting May 2006
Required tools
You need the following tools to do the installation:
Phillips #2 screwdriver
ESD grounding wrist strap
Antistatic mat
Electrical specifications
Parameter Value
V880 V890
Input
Nominal voltage range
Maximum current AC RMS
AC operating range
Nominal frequencies
100-240 V AC,
autoranging
15.0 A @100 VAC
90-264 V rms, 47-63Hz
50 Hz or 60 Hz
200-240 V AC,
autoranging
8.0 A @200 VAC
180-264 V rms, 47-63Hz
50 Hz or 60 Hz
Maximum DC power output 2240 W 2509 W
Maximum system AC power
consumption
3000 W 3200 W
Maximum system heat dissipation 10308 BTU/hr 10912 BTU/hr
Volt-ampere rating 1515 VA with 1120 Watt load
(PF=0.99)
2078 VA with 1629 Watt load
(PF=0.98)
Wall plug type
United States
Non-United States
NEMA 5-15P
Power cords must be
obtained locally
NEMA 6-15P
Power cords must be
obtained locally
CPU plug type IEC 320 IEC 320