Sun Microsystems V880 Server User Manual


 
Troubleshooting
168 Avaya CMS Sun Fire V880/V890 Installation, Maintenance, and Troubleshooting May 2006
Probing disk drives
This test checks all disk drives.
Symptom: The internal disk drives are reporting errors.
Solution: To check the status of the disk drives:
1. Enter:
/usr/sbin/shutdown -y -i0 -g0
This shuts down the system.
2. At the ok prompt, enter the following commands:
setenv auto-boot? false
reset-all
The system resets.
3. Enter:
probe-scsi
The program displays a message that is similar to the following:
Note:
Note: The actual response depends on the number of disk drives that are installed in
the system. This example shows six disk drives and the disk drive backplane.
4. Fix any obvious errors, such as disconnected backplane cables or disk drives not
completely inserted.
5. When you finish testing, enter the following commands:
CAUTION:
!
CAUTION: If you fail to enter these commands, any reboots that you do in the future will stop
at the boot prompt instead of proceeding through the normal boot-up process.
setenv auto-boot? true
boot -r
The system reboots.
LiD HA LUN --- Port WWN --- -----Disk description -----
0 0 0 21000004cf72f08f SEAGATE ST373405FSUN3660438
1 1 0 21000004cf721553 SEAGATE ST373405FSUN3660438
2 2 0 21000004cf7213ea SEAGATE ST373405FSUN3660438
6 6 0 508002000016b5b1 SUNW SUNWGS INT FCBPL9224
3 3 0 21000004cf72114b SEAGATE ST373405FSUN3660438
4 4 0 21000004cf7211ae SEAGATE ST373405FSUN3660438
5 5 0 21000004cf7214a3 SEAGATE ST373405FSUN3660438