Symbol Technologies WS 2000 Switch User Manual


 
WS 2000 Wireless Switch System Reference Guide7-22
Setting the Trap Configuration
To set the trap notification destination for SNMP, select System Configuration --> SNMP Access --> SNMP Trap
Configuration from the left menu.
Setting the Trap Configuration for SNMP v1/v2c
To set the trap notification destination for the SNMP v1/v2c servers, add one or more entries to SNMP v1/v2c Trap
Configuration table.
1. Click the Add button to add a new entry to the table.
2. Specify a Destination IP addresses for the systems that will receive notification when an SNMP trap is generated.
3. Specify a destination User Datagram Protocol (UDP) port for receiving the traps that are sent by SNMP agents.
UDP offers direct connection for sending and receiving datagrams over an IP network.
4. Specify a Community name that matches one of the community names added on the SNMP Access screen.
1. Click the Add button to create a new entry in the Access
Control table.
2. Specify the IP address for the user(s) that have access.
Enter an IP address only in the Starting IP Address
column to specify an address for a single SNMP user.
Enter both the Starting IP Address and Ending IP
Address columns to specify a range of addresses for
SNMP users.
3. Click Ok to save changes and return to the SNMP Access
screen.