Caring for Your Printer
4
User Manual
4-23
Cleaning for ink smears: paper feed rollers
Approximate time to complete: 5 minutes
If you have already performed the “Cleaning for ink smears: internal paper
path” cleaning procedure earlier in this chapter but problems persist, clean
the upper and lower paper feed rollers.
The paper feed rollers carry the print media from the media tray and manual
feed slot through the printer. Occasionally, stray ink particles become
attached to the paper feed rollers causing ink smears on prints. When this
occurs, you must clean the paper feed rollers using alcohol-soaked swabs.
Refer to “Using isopropyl alcohol” on page 4-20 for more information.
Sample ink smear: paper feed rollers
9101-61