Tektronix 340 Printer User Manual


 
Technical Notes
A
User Manual
A-13
Specifications
Printer tilt
Place the printer on a level surface with no more than 3° tilt in any direction.
Equivalent to raising one corner of the printer approximately 2 cm
(0.75 inches.)
Caution
Tilting the printer more than 3° causes drum fluid to leak from
the maintenance tray resulting in damage to your printer not
covered by the printer’s warranty.
Temperature
Operating: 10° C to 35° C (50° F to 95° F)
Nonoperating: –30° C to +60° C (–22° F to 140° F)
Storage: –30° C to +60° C (–22° F to 140° F)
Humidity
Operating: 10% to 80% Relative Humidity, noncondensing
Nonoperating: 10% to 95% Relative Humidity, noncondensing
Altitude
Operating: 0 to 2,400 meters (0 to 8,000 feet)
Nonoperating: 0 to 15,000 meters (0 to 50,000 feet)
Primary voltage ranges (switch-selectable)
87 – 128 VAC, 115 VAC nominal 174 – 250 VAC, 220 VAC nominal
Frequency range
48 to 66 Hz
AC input ratings
115 VAC, 10 Amps 220 VAC, 5 Amps
Printing resolution and speed*
300 x 300 dpi color print on paper: 4 pages per minute
300 x 300 dpi color print on transparency: 2 pages per minute
600 x 300 dpi color print on paper: 2 pages per minute (optionally available)
* Left and right margins set to 0.3 in. (7.4 mm) or larger.