4.26 Fluorescent lamp 4 Replacement Procedure
4
4.26 Fluorescent lamp
This system uses LCD modules from the following suppliers. The procedure for replacing
the fluorescent lamp is different for each LCD module. Refer to the appropriate procedure.
Type Part No. Supplier Section
VF2093P01
Chimei
4.26.1
VF2058P01
Samsung
4.26.2
14.1
inch
(XGA)
G33C00015110
TMD
4.26.3
G33C0000M110
Chimei
4.26.4
G33C0000K110
LG.Philips
4.26.5
G33C0000L110
Samsung
4.26.6
G33C0000Q110
Sharp
4.26.7
15.0
inch
(XGA)
G33C0000Q310
Sharp
4.26.7
G33C0000R110
LG.Philips
4.26.8
15.0
inch
(SXGA+)
G33C0000P110
Sharp
4.26.9
NOTE: - When working with a LCD module, always use a flat, grounded table.
- Handle the backlight unit in the environment without dust, such as on the clean
bench. Keep the worktable free from any screws or other material that may
scratch the LCD surface.
- Use an anti-static or protective sheet.
- When replacing the FL unit, cover with a finger protector or similar to prevent
soiling or scratching the LCD panel.
- Be careful when handling the lamp. Excessive force may break the lamp.
- Be careful not to soil or deform the lamp reflector.
- Make sure that the power of the LCD module is turned off before connecting or
disconnecting cables and connectors.
Satellite A40 Maintenance Manual (960-458) 4-69