Toshiba A40 Laptop User Manual


 
4 Replacement Procedure 4.26 Fluorescent lamp
4.26.3 Replacing the 14.1 Inch XGA TMD Fluorescent lamp
The following describes the procedure for replacing the fluorescent lamp (See Figure 4-63 to
Figure 4-74)
Disassembling Fluorescent lamp
Peeling off the tapes and insulation sheets
1. Flip the module over and place it on a flat surface that is free of foreign objects.
2. In the order (1), (2), and (3) shown in Figure 4-63, remove the tape for fixing the FL
tube cable, two pieces of tape on the bezel that are close to the FL tube, and the X-
PCB insulation sheet.
CAUTION: (1) Be careful not to damage the TAB.
(2) Leave the insulation sheet on the bezel to allow the reuse of the sheet.
F9402
製品 ラベル
>PC-GF13<
BL S/N ラベル
FL破棄ラベル
CAUTIONラベル
3
22
1
Product label
CAUTION label
BL S/N label
Label (cautions for disposal of FL tubes)
Figure 4-63 Replacing 14 Inch TMD fluorescent lamp (1)
4-80 Satellite A40 Maintenance Manual (960-458)