4.24 Touch pad/Fingerprint sensor board 4 Replacement Procedures
5. Peel off the membrane switch adhered with the double-sided tape and remove the tip
point of the FPC (connector terminal side) from the hole.
6. Remove the following screw and fingerprint sensor board adhered with the double-
sided tape.
• M2×3B S-THIN HEAD ×1
Fingerprint sensor board
Membrane switch
M2x3B S-THIN HEAD
Figure 4-36 Removing the touch pad/fingerprint sensor board (2)
PORTÉGÉ A600 Maintenance Manual (960-710) [CONFIDENTIAL] 4-63