Vanguard Managed Solutions 6455 Network Card User Manual


 
Installation and Replacement 3-25
Modifying Your Vanguard 6435/6455
Adding/Removing
a FLASH/Data
Compression/
Encryption SIMM
Figure 3-13 shows how to add or remove a FLASH or Data Compression SIMM for
the Vanguard 6435/6455. Refer to Figure 3-10 for the location of the SIMM slots:
Data Compression SIMM or Encryption SIMM: Slot U108
FLASH SIMM: Slot U57
Caution
Be careful when installing a Data Compression SIMM or a FLASH SIMM. These
SIMM slots look identical and you may accidently place a SIMM in the wrong
SIMM slot which could damage the equipment.
Caution
Some components used in the 6435/6455 are sensitive to static electric discharges;
static electric discharges can cause damage to internal components. Use proper
handling and grounding precautions whenever handling cards and components.
Mise en Garde
Certains composants du 6435/6455 sont sensibles aux décharges électrostatiques qui
peuvent les endommager. Prenez les dispositions et précautions de mise à la terre
nécessaires lors de la manipulation de cartes et de composants.
Vorsicht
Einige im 6435/6455 verwendeten Komponenten sollten keinen elektrostatischen
Entladungen ausgesetzt werden, durch die interne Bauteile beschädigt werden
können. Wenden Sie die entsprechenden Maßnahmen zur Erdung und zum Schutz
vor statischen Ladungen bei der Handhabung von Karten und Komponenten an.
Note
The location of the Data Compression (DCC/DSP) SIMM/Encryption SIMM
and the FLASH SIMM are indicated on the motherboard as shown in
Figure 3-13.