VXI VX1410A Computer Hardware User Manual


 
STATus Subsystem
3–48
VX1410A & VX1420A IntelliFrame Mainframe Instruction Manual
STATus:OPERation:VXIMonitor:SYSFail?
Queries the time when the VXI SYSFAIL signal was asserted. The time is
relative to the mainframe power-on time.
If there are multiple occurrences of the VXI SYSFAIL signal, only the time of
the first assertion is saved. Reading the time enables it to record the next
SYSFAIL signal assertion time.
When no SYSFAIL is detected, the query returns a value of 0 in all fields. At
power-on, or after restarting VXIMonitor the values of all fields are set to 0.
There is no command associated with this query.
STATus:OPERation:VXIMonitor:SYSFail?
Parameter Query response
Not Applicable <Hour>,<Minute>,<Second>
0
None
None
Query: STAT:OPER:VXIM:SYSF?
Response: 12,3,1
STATus:OPERation:VXIMonitor:CONDition?
STATus:OPERation:VXIMonitor:ENABle
STATus:OPERation:VXIMonitor?
Syntax
Parameters
Reset Value
Errors and Events
Dependencies
Examples
Related Commands