VXI VX1410A Computer Hardware User Manual


 
SYSTem Subsystem
3–120
VX1410A & VX1420A IntelliFrame Mainframe Instruction Manual
SYSTem:COMMunicate:SERial:PRESet
Presets logical groups of RS-232 port control parameters. The default mode sets
all RS-232 settings to a known state. The RAW and TERMinal modes change
only a subset of the parameters. Use RAW when connected to a computer and
use TERMinal when connected to a computer display terminal.
The command “T” followed by a new line character (^J) configures the RS-232
port for terminal operation when it is currently in the RAW mode.
There are no associated queries with these commands.
Table 3–15 lists the preset values for each PRESet command.
Table 3–15: Effects of :PRESet on serial port parameters
SERial port parameter [:ALL] :RAW :TERMinal
BAUD 9600 NC
1
NC
1
BITS 8 NC
1
NC
1
CONTrol:RTS ON NC
1
NC
1
ECHO OFF OFF ON
ERESponse OFF OFF ON
LBUFfer OFF OFF ON
PACE NONE NONE XON
PARity NONE NC
1
NC
1
SBITs 1 NC
1
NC
1
1
The entry NC in a field means the value is not changed.
SYSTem:COMMunicate:SERial:PRESet[:ALL]
SYSTem:COMMunicate:SERial:PRESet:RAW
SYSTem:COMMunicate:SERial:PRESet:TERMINAL
None
Not Applicable
None
See Table 3–15.
Command: SYST:COMM:SER:PRES:TERM
All SYSTem:COMMunicate:SERial commands
Syntax
Parameters
Reset Value
Errors and Events
Dependencies
Examples