VXI VX1410A Computer Hardware User Manual


 
Getting Started
1–16
VX1410A & VX1420A IntelliFrame Mainframe Instruction Manual
NOTE. The 13.25-inch vertical clearance is only valid for the mainframe without
the plastic feet, rails and cable trays. Refer to Figures 4–2, 4–4, and 4–5 on
pages 4–11, 4–12, and 4–13 for information on vertical clearances of the
mainframe with cable tray options.
14.0 in
(355.6 mm)
12.0 in
(304.8 mm)
1.5 in
(38.1 mm)
Left-front rail
0.5 in (12.7 mm)
(For correct position of
securing holes)
Figure 1–8: Vertical clearance for rack installation (standard mainframe)
7. Select the mounting method according to the rack type.
To mount the slide-out tracks with the front and rear flanges outside of the
front and rear rails, use method A shown in Figure 1–9 when doing step 8.
Add a bar nut to the installation only if the rails have untapped holes.
To mount with front and rear flanges inside of the rails, use mounting
method B shown in Figure 1–9 when doing step 8. This mounting method
assumes untapped holes.