WHP Wireless DL360 Server User Manual


 
118 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide
server documentation for further requirements.
NOTE: It is recommended that no more than two DLT drives per bus
exist.
If using an external DLT drive that requires a SCSI terminator to be secured
to the unused SCSI IN connector on the back of the drive, be sure the SCSI
terminator is connected.
DLT drives can be daisy chained, but do not connect more than three units
per SCSI controller. The last DLT drive in the chain requires the SCSI
terminator.
Check cables for damaged or bent connectors.
An error occurs during backup, but the backup is completed
Action: Contact the software vendor for more information about the message. If
the error does not disrupt the backup, you may be able to ignore the error.
Fan Problems
List of Problems:
General fan problems are occurring ...........................................................................................118
Hot-plug fan problems are occurring..........................................................................................119
General fan problems are occurring
Action:
1. Be sure the fans are properly seated and working.
a. Follow the procedures and warnings in the server documentation for
removing the access panels and accessing and replacing fans.
b. Unseat, and then reseat, each fan according to the proper procedures.
c. Replace the access panels, and then attempt to restart the server.
2. Be sure the fan configuration meets the functional requirements of the server.
Refer to the server documentation.
3. Be sure no ventilation problems exist. If you have been operating the server
for an extended period of time with the access panel removed, airflow may
have been impeded, causing thermal damage to components. Refer to the