WHP Wireless DL360 Server User Manual


 
48 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide
After installing DIMMs, use RBSU to configure the system for online spare
memory support ("Configuring Online Spare Memory" on page 69
).
Installing DIMMs
1. Power down the server ("Powering Down the Server" on page 25).
2. Extend the server from the rack, if applicable ("Extending the Server from
the Rack" on page 26
).
3. Remove the access panel ("Removing the Access Panel" on page 27
).
4. If installed, remove the half-length expansion board ("Expansion Board" on
page 57
).
5. Open the DIMM slot latches.
6. Install the DIMM.
7. If removed, reinstall the half-length expansion board ("Installing an
Expansion Board" on page 58
).
8. Install the access panel ("Installing the Access Panel" on page 28).
9. If you are installing DIMMs in an online spare configuration, use RBSU to
configure this feature ("Configuring Online Spare Memory" on page 69).