WHP Wireless DL360 Server User Manual


 
44 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide
The server uses embedded PPMs as DC-to-DC converters to provide the proper
power to each processor.
CAUTION: To prevent thermal instability and damage to the
server, do not separate the processor from the heatsink. The processor,
heatsink, and retaining clip make up a single assembly.
CAUTION: To prevent possible server malfunction and
damage to the equipment, do not mix processors of different types.
To install a processor:
1. Power down the server ("Powering Down the Server" on page 25
).
2. Extend the server from the rack, if applicable ("Extending the Server from
the Rack" on page 26
).
3. Remove the access panel ("Removing the Access Panel" on page 27
).
4. Release the processor retaining clips and processor locking lever.