WHP Wireless DL360 Server User Manual


 
Troubleshooting 163
Controller Communication Failure Occurred
Description: Controller communication failure occurred. ADU was unable to
successfully issue commands to the controller in this slot.
Action:
1. Be sure all cables are properly connected and working.
2. Be sure the controller is working, and replace if needed.
Controller Detected. NVRAM Configuration not Present
Description: EISA NVRAM does not contain a configuration for this controller.
Action: Run the server setup utility to configure the NVRAM.
Controller Firmware Needs Upgrading
Description: Controller firmware is below the latest recommended version.
Action: Run Options ROMPaq to upgrade the controller to the latest firmware
revision.
Controller is Located in Special "Video" Slot
Description: Controller is installed in the slot for special video control signals. If
the controller is used in this slot, LED indicators on front panel may not function
properly.
Action: Install the controller into a different slot, and run the server setup utility
to configure NVRAM. Then, run ACU to configure the controller.