Troubleshooting 165
Drive (Bay) X Firmware Needs Upgrading
Description: Firmware on this physical drive is below the latest recommended
version.
Action: Run Options ROMPaq to upgrade the drive firmware to the latest
revision.
Drive (Bay) X has Insufficient Capacity for its Configuration
Description: Drive has insufficient capacity to be used in this logical drive
configuration.
Action: Replace this drive with a larger capacity drive.
Drive (Bay) X has Invalid M&P Stamp
Description: Physical drive has invalid monitor and performance data.
Action: Run the server setup utility to properly initialize this drive.
Drive (Bay) X Has Loose Cable
Description: The array controller could not communicate with this drive at
power-up. This drive has not previously failed.
Action:
1. Be sure all cables are properly connected and working.
2. Power up the system and attempt to reconnect data/power cable to the drive.
3. If the problem persists, replace the cable.
4. If the problem persists, replace the drive.