monitor port counters 69
Defaults — All types of statistics are displayed for all ports. MSS
refreshes the statistics every 5 seconds. This interval cannot be
configured. Statistics types are displayed in the following order by
default:
Octets
Packets
Receive errors
Transmit errors
Collisions
Receive Ethernet statistics
Transmit Ethernet statistics
Access — All.
History—Introduced in MSS Version 3.0.
Usage — Each type of statistic is displayed separately. Press the Spacebar
to cycle through the displays for each type.
If you use an option to specify a statistic type, the display begins with that
statistic type. You can use one statistic option with the command.
Use the keys listed in Table 15 to control the monitor display.
For error reporting, the cyclic redundancy check (CRC) errors include
misalignment errors. Jumbo packets with valid CRCs are not counted. A
short packet can be reported as a short packet, a CRC error, or an
overrun. In some circumstances, the transmitted octets counter might
increment a small amount for a port with nothing attached.
Table 15 Key Controls for Monitor Port Counters Display
Field Description
Spacebar Advances to the next statistic type.
Esc Exits the monitor. MSS stops displaying the statistics and displays a new
command prompt.
c Clears the statistics counters for the currently displayed statistics type. The
counters begin incrementing again.