System Management Commands
4-31
4
Command Usage
The user-entered data cannot contain spaces. The banner configure
company command interprets spaces as data input boundaries. The use of
underscores ( _ ) or other unobtrusive non-letter characters is suggested for
situations where whitespace is necessary for clarity.
Example
banner configure dc-power-info
This command allows the administrator to configure the DC power information
displayed in the banner. Use the no form to remove the DC power information from
the banner display.
Syntax
banner configure dc-power-info floor floor-id row row-id rack rack-id
electrical-circuit ec-id
no banner configure dc-power-info [floor | row | rack | electrical-circuit]
floor-id - The floor number. (Maximum length: 32 characters)
row-id - The row number. (Maximum length: 32 characters)
rack-id - The rack number. (Maximum length: 32 characters)
ec-id - The electrical circuit ID. (Maximum length: 32 characters)
Default Setting
None
Command Mode
Global Configuration
Command Usage
The user-entered data cannot contain spaces. The banner configure
dc-power-info command interprets spaces as data input boundaries. The use
of underscores ( _ ) or other unobtrusive non-letter characters is suggested for
situations where whitespace is necessary for clarity.
Example
banner configure department
This command allows the administrator to configure the department information
displayed in the banner. Use the no form to remove the department information from
the banner display.
Console(config)#banner configure company Edgecore
Console(config)#
Console(config)#banner configure floor 3 row 15 rack 24
electrical-circuit 48v-id_3.15.24.2