Alvarion SW VERSION 5.1 Network Router User Manual


 
Menus and Parameters
Operation and Administration
99
Table 4-2: Parameters not changed after Set Complete Factory/Operator Defaults
Parameters Group Parameter
Unit Control Parameters All Passwords
FTP Server IP address* (see note below)
FTP Gateway IP address* (see note below)
FTP User Name* (see note below)
FTP Password* (see note below)
Ethernet Port Negotiation Mode
Air Interface Parameters Selected Sub-Band (AU)
Frequency (AU)
DFS Required by Regulations (AU)
Frequency Subset (AU)
Antenna Gain (AU)
Country Code Parameters Selected Country Code
NOTE
The FTP parameters are not set to their default values after Set Complete Operator Defaults.
However, they are set to their default value after Set Complete Factory Defaults. Note that in this
case they are set to the default values immediately upon selecting the Set Complete Factory
Default option (even before the next reset).
4.2.3.2.1.2 Set Partial Factory Defaults
Select this option to reset the unit to the standard Factory Default configuration,
excluding the parameters that are required to maintain connectivity and
management access. The parameters that do not change after Set Partial Factory
Defaults are listed in Table 4-3.
Table 4-3: Parameters that are not changed after Set Partial Factory/Operator
Defaults
Parameters Group Parameter
Unit Control parameters Passwords
Ethernet Port Negotiation Mode
FTP Server IP address