APC 15000 RAID Power Supply User Manual


 
Controller Management
007-5510-002 81
3.8 Other Utilities
3.8.1 APC UPS SNMP Trap Monitor
APC_UPS displays the status of the APC UPS SNMP trap monitor (Figure 3–61).
Figure 3–61 APC UPS SNMP Trap Monitor Status
APC_UPS CLEAR_FAULTS will delete all pending APC UPS faults from the fault list. All APC UPS
events that disabled writeback caching will be cleared.
3.8.2 API Server Connections
The API command displays the current status of the API connections (Figure 3–62).
Figure 3–62 Displaying Status of API Connections
API DISABLE temporarily enables/disables the establishment of connections to the API server. When
disabled, users at remote locations will be unable to establish a new API connection until an
API ENABLE command is issued. This command only provides control over API connections during the
current power cycle.
API STATS displays the collected statistics on API connections
(Figure 3–63).
API CLEARSTATS resets the collected statistics.
Figure 3–63 API Server Connection Statistics
3.8.3 Changing Baud Rate for the CLI Interface
The CONSOLE command displays the current serial console setting (Figure 3–64) of the controller.
15000 [1]: apc_ups
APC UPS SNMP trap monitor is off.
No APC UPS faults detected via SNMP trap.
15000 [1]: api
API Server connections are currently -- ENABLED--