Avaya C460 Switch User Manual


 
Chapter 2 Avaya C460 CLI Commands
Avaya C460 Reference Guide 123
Example:
set ppp baud-rate
User level: read-write, admin.
Use the set ppp baud-rate command to define the baud rate used in PPP
sessions.
L You mujst set the peer baud rate to the same value as the host.
The syntax for this command is:
set ppp baud-rate <9600|19200|38400>
Example:
set ppp chap-secret
User level: admin.
Use the set ppp chap-secret command to configure the “shared secret” used
in PPP sessions with CHAP authentication. The chap-secret is not transferable via
the configuration upload/download mechanism.
The syntax for this command is:
set ppp chap-secret <chap-secret>
Example:
set ppp incoming timeout
User level: read-write, admin.
Use the set ppp incoming timeout command to set the number of minutes
until the system automatically disconnects an idle PPP incoming session.
C460-1# set ppp authentication incoming chap
PPP requires CHAP authentication for incoming sessions.
C460-1# set ppp baud-rate 38400
ppp baud rate was set to 38400
chap-secret The shared secret, 4 to 32 characters.
C460-1(super)# set ppp chap secret hush
PPP shared secret for CHAP authentication is set