144 DCS-200 • User’s Guide
_K==oÉãçíÉ=`çåíêçä
Remote Commands
• Parameters:
-i (input): 1 - 9
-s (saturation): 0 - 150 (Default: 100)
• Query Format: ISAT -i (input) -?
• Query Response: ISAT -i (input) -s (sat) --min 75 --max 125
• List Response: 0:"RGB"
1:"SMPTE"
fpbi
• Description: Selects the specified input as the current input to display. This
command will perform the valid sync check, route the input, recall video if saved
or acquire source if not saved. Includes the -f (file) parameter option. Also, the
IMAP will be updated for the input if the file parameter is specified.
• Command Format: ISEL -i (input) -f (file
• Parameters: -i (input): 1 - 9
-f (file): 1 - 64; If specified, updates the File Association menu to reflect
the selected file number. If not specified, uses the file number specified
in the ICREC query.
• Query Format: ISEL -?
• Query Response: ISEL -i (input)
fpif`b=
• Description: Input Sync Slice Threshold Adjust. This command is only valid for
analog inputs.
• Command Format: ISLICE -i (input) -t (threshold)
• Parameters: -i (input): 1 - 8 for adjustments (7 & 8 only if itype is analog)
-t(threshold): 8 - 256mV; +8 increments (default: 128mV)
• Query Format: ISLICE -i (input) -?
• Query Response: ISLICE -i (input) -t (threshold) --min 8 -- max 256
fpjm=
• Description: Adjust Input Sample mode. This command is only adjustable for
analog input types. Other input types will provide query information only.
• Command Format: ISMP -i (input) -s (sample mode)
• Parameters:
-i (input): 1 - 8 for adjustments (7 & 8 only if itype is analog); 1 - 9 for
query
-s (sample mode): 0 - over sample, 1 - 1:1 sampling (Default: 1:1)
• Query Format: ISMP -i (input) -?
• Query Response: ISMP -i (input) -s (sample mode) --min 0 -- max 1