DCS-200 • User’s Guide 153
_K==oÉãçíÉ=`çåíêçä
Remote Commands
icbk
• Description: Sets the mode for the selected log. When selected, the messages
for that log will be written to flash every time interval specified in (LINT).
• Command Format: LFEN -l (log) -m (mode)
• Parameters: - l (log): 0-combined, 1-debug, 2-warning, 3-error
-m (mode): 0 - disable, 1 - enable
• Query Format: N/A
• Query Response: N/A
ifkq
• Description: Sets the time interval for writing the enabled logs to flash.
• Command Format: LINT -t (time interval)
• Parameters: -t (time interval): 1 - 60 seconds
• Query Format: N/A
• Query Response: N/A
il`hlrq
• Description: Controls the lockout mode of the front panel. With full lockout mode
enabled, all keys and menu will be deactivated. The executive mode will lock out
all but the input bus keys (1 through 8, SDI, and LOGO).
• Command Format: LOCKOUT -m (mode) -f
• Parameters: -m (mode): 0 - disable, 1 - full lockout, 2 - executive mode
(default: 0 - disable)
-f: Command from front panel
• Query Format: LOCKOUT -?
• Query Response: LOCKOUT -m (mode) -- min 0 -- max 2
lpq^q
• Description: Query only command for the output status type and format.
• Query Format: OSTAT -?
• Query Response: OSTAT -t "(output type)" -f "(output format)"
mobsfbt=
• Description: Query only command for the input, key and black button status on
preview. If the black, key, or scaler path is not present on preview, then these
options are not returned.
• Parameters: -i (input): 1 - 9
-k: key on preview
-b: black on preview
-l: logo on preview
-a: A or B path of scaler input on preview