DCS-200 • User’s Guide 149
_K==oÉãçíÉ=`çåíêçä
Remote Commands
10:"800x600 @50"
11:"800x600 @56"
12:"800x600 @59.94"
13:"800x600 @60"
14:"800x600 @72"
15:"800x600 @75"
16:"800x600 @85"
lpo`
• Description: Selects the input source for the preview output (preview or
program).
• Command Format: OSRC -s (source)
• Parameters: -s (source): 0-preview, 1-program
• Query Format: OSRC -?
• Query Response: OSRC -s (source)
• List Format: OSRC --list
• List Response: 0:"PREVIEW"
1:"PROGRAM"
lpvk`=
• Description: Output Sync Type Adjust.
• Command Format: OSYNC -o (output) -s (sync)
• Parameters:
-o (output): 1 - DVI, 2 - Analog, 3 - Preview DVI, 4 - Preview Analog
-s (sync): 1 = +H+V, 2 = +H-V, 3 = -H+V, 4 = -H-V, 5=CSync for analog
only (Defaults: DVI : +H+V, analog: -H-V)
• Query Format: OSYNC -o (output) -?
• Query Response: OSYNC -o (output) -s(sync) --min 1 --max 4 (max returned for
analog is 5)
• List Format: OSYNC -o (output) --list
• List Response: 1:"+H+V"
2:"+H-V"
3:"-H+V"
4:"-H-V"
5.”CSync” (returned for analog only)
lqmj=
• Description: Output Test Pattern Mode
• Command Format: OTPM -o (output) - m (mode)