Daylight Display Systems 125 BARCO DLite Software
Chapter 9
Trouble shooting
General
THERE IS NO PICTURE ON THE WALL AND THE DIGITIZER IS NOT
OPERATIONAL
Check Check the power on the digitizer
Make sure the digitizer isnt in stand-by mode
THERE IS NO PICTURE ON THE WALL AND THE DIGITIZER IS FULLY
OPERATIONAL
Check the main power of the wall (every single fuse)
Check the power entering the modules (min 190 V)
Check the selected video source and its connections to the digitizer
Check the cable between the digitizer and the first module
Bridge the fist module (data cable), and Check again
Check the contrast of the wall
Check the scaling of the active video
Check the fiberlink power status. In the DLite Soft Fiberlink Window you are able to shut down the power to
the fiberlink transmitter resulting in an empty-picture wall.
Check the content source (black ??)
THERE IS NO COMMUNICATION BETWEEN THE PC AND THE MODULES /
DIGITIZER
Check the power on the wall and digitizer
Check whether the DLite control soft is set on-line (bottom right square in the DLite main window should be
colored green)
Check the communication setup of the software (communication port / baud rate)
In case of a portable PC Check whether the serial com port is in fact switched on, and not used by another
resident program
Check the RS232 cable (max 30 m long) itself and whether it is plugged in right on both sides