Barco R98500400 Projector Accessories User Manual


 
Chapter 7 Control Software/Devices
Daylight Display Systems 95 BARCO DLite Software
value is proportional to the Light Output (expressed in Nit) E.g. when the ambient light is only half as bright as
normal, you can set the reference number to 250 instead of 500. The AEC will be calibrated according to this
number. To Calibrate the AEC push the AEC Calibration button and wait a second. All measurements will
return a value proportional to the calibration value.
At the bottom of the tab you can push the Sensor Weight button to pull up a next box where you can change
the sensor weight according to its importance. The next window will appear:
To be able to assign weights to the individual sensors, one can perform 100 measurements on each sensor.
In this way, the chart for each sensor is a reference to the measured light of this sensor. If one sees one or
more sensors having unstable measurements, the sensors can be weighted by the ens user.
After youve pushed either one of the buttons the Sensor weight AEC box appears
SENSOR WEIGHT AEC
Select a sensor by selecting a portion of the pie diagram. The portion selected depends on the sensor
required, represented in the Sensor Representation tab. At the bottom are visible the according statistics in
the Statistics tab.
Altering the sensor weight can be done by pushing the up and down buttons in the Sensors tab. Check
buttons in the Sensors tab are also visable. Switching on these checkbuttons make sure that the weight of the
respective sensors will change in the same proportional way.
It is also possible to hold the weight of a specific sensor while changing the other sensors weights. This can
be accomplished by right clicking the portion of the pie corresponding to the desired sensor provided this
portion of the pie isnt already selected in anyway.