Black Box Version 1.0 Network Card User Manual


 
10.2.1 Protection against dangerous affects
The protection of the equipment against dangerous interfering affects meets the requirements of
ITU-U K20/K.21
10.2.2 Surge safety
Parameter Description Note
The resistance between the
ground terminal and isolated parts
of the device
0,1 Ohm
Insulation resistance of the device
electrical circuit
20 MOhm (normal climatic
conditions)
5 MOhm (high temperature)
1 MOhm (high humidity)
Test voltage for ungrounded
electrical circuit relative to the
case of the device
500 V (amplitude, normal
climatic conditions)
300 V (amplitude, high
humidity)
Test voltage of isolation of
electrical circuit, galvanically
disconnected with the ground
500 V (amplitude, normal
climatic conditions)
300 V (amplitude, high
humidity)
Without
discharge
within 1
minute
Test voltage of 50 Hz accepted by
the line interface
> 2000 V
rms
relative to
ungrounded device elements
> 1500 V
rms
relative to
grounded device elements
Within 2 s
10.3 10.3 Climatic conditions
The units are engineered to operate in the following climatic conditions:
• air temperature -5… +45°C;
• relative air humidity 95% at 25°C.
The equipment preserves all its characteristics at 450 Torr (60 KPa)
The storage conditions: -50…+50°C.
The equipment can withstand all means of transport (including airplanes), i.e. it withstands the
90-Torr (12 KPa) atmospheric pressure at -50°C.
Version: 1.0 Page. 82 of 95