7. Secure the Fusing Unit with the two long screws.
Fig. 5-23 Secure the retaining clips
8. Move the Fusing Unit Pressure Release Levers to the SET position.
Fig. 5-24 Set the Levers to the SET position
9. Install the Fuser Cleaner and the Oil Bottle into the new Fusing Unit
and Lock the Oil Bottle Lock Levers and the Fuser Cleaner Lock
Levers. Be careful not to spill oil inside the printer. This could
damage the printer.
Note
If the condition of the Fuser Cleaner is poor, we recommend that you
replace the Fuser Cleaner at the same time as the Fusing Unit. The life
counter for the Fuser Cleaner will also need to be reset. Please refer to
page 5-10 for instructions.
Partially used Oil Bottles can be reused with a new Fusing Unit.
Please wait for 30 minutes after installing a new Fusing Unit to allow
the oil to circulate completely through the Heat Roller.
10. Close the Top Cove and plug the printer into the AC outlet.