Trap Messages 3-5
Configuring the Trap Table
SABM/DISC with wrong link address 198
The HDLC frame processor task for the port has received an improperly
addressed frame from the subscriber. This situation usually occurs when the port
and subscriber devices are both conÞgured as logical DCEs or logical DTEs.
Severity Informational (Level 4)
Action Modify the Port record so that one end of the connection is a
logical DCE and the other is a logical DTE.
Illegal TC/Gen Clk Combination 219
The software has determined that a port is set to run at an illegal line speed
(throughput class).
Severity Critical (Level 1)
Action This is probably a conÞguration error. Check the Port record and
change the throughput class, if necessary.
Excessively noisy line 250
Self-explanatory.
Severity Minor (Level 3)
Action Check the communications line and cables.
LP Buf Usage exceeded T: “n” C: “n” 304
The RLP statistic Percentage of Buffers in Use has exceeded the threshold
(T: ÒnÓ) that was set by the user. (C: ÒnÓ is the current value.)
Severity Informational (Level 4)
Action If this happens frequently, you may need to reroute some trafÞc.
LP Msg Queued exceeded T: “n” C: “n” 305
The RLP statistic Number of Queued Messages has exceeded the threshold
(T: ÒnÓ) that was set by the user. (C: ÒnÓ is the current value.)
Severity Informational (Level 4)
Action If this happens frequently, you may need to reroute some trafÞc.
LP Rcv Frm/Sec exceeded T: “n” C: “n” 306
The RLP statistic Received Frames/Sec has exceeded the threshold (T: ÒnÓ) that
was set by the user. (C: ÒnÓ is the current value.)
Severity Informational (Level 4)
Action If this happens frequently, you may need to reroute some trafÞc.