DLP- D244 Use the Reinitialization Tool to Clear the Database and Upload Software (Windows)
DLP-D244 Use the Reinitialization Tool to Clear the Database and Upload
Software (Windows)
Caution Restoring a node to the factory configuration deletes all cross-connects on the node.
Step 1 Insert the system software CD into the computer CD-ROM drive. If the CTC Installation Wizard appears,
click Cancel.
Step 2 From the Windows Start menu, choose Run. In the Run dialog box, click Browse and navigate to the
CISCO15454SDH folder on the software CD.
Step 3 In the Browse dialog box Files of Type field, choose All Files.
Step 4 Choose the RE-INIT.jar file and click Open. The NE Re-Initialization window appears (Figure 19-12).
Figure 19-12 Reinitialization Tool
Step 5
Complete the following fields:
GNE IP—If the node you are reinitializing is accessed through another node configured as a gateway
network element (GNE), enter the GNE IP address. If you have a direct connection to the node, leave
this field blank.
Node IP—Enter the node name or IP address of the node that you are reinitializing.
Purpose This task reinitializes the ONS 15454 SDH using the CTC
reinitialization tool on a Windows computer. Reinitialization uploads a
new software package to the TCC2/TCC2P cards, clears the node
database, and restores the factory default parameters.
Tools/Equipment ONS 15454 SDH System Software CD, Version 7.2
Java Runtime Environment (JRE) 1.4.2 or JRE 5.0 must be installed on
the computer to log into the node at the completion of the
reinitialization. The reinitialization tool can run on JRE 1.3.1_02, JRE
1.4.2, or JRE 5.0.
Prerequisite Procedures DLP-D60 Log into CTC, page 17-49
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Superuser