Step 1 Insert the system software CD containing the reinit tool, software, and defaults database into the
computer CD-ROM drive. If the CTC Installation Wizard appears, click Cancel.
Step 2 To find the recovery tool file, go to the CISCO15454SDH directory on the CD (usually
/cdrom/cdrom0/CISCO15454SDH).
Step 3 If you are using a file explorer, double-click the RE-INIT.jar file. If you are working with a command
line, run java -jar RE-INIT.jar. The NE Re-Initialization window appears (Figure 19-12).
Step 4 Complete the following fields:
GNE IP—If the node you are reinitializing is accessed through another node configured as a GNE,
enter the GNE IP address. If you have a direct connection to the node, leave this field blank.
Node IP—Enter the node name or IP address of the node that you are reinitializing.
User ID—Enter the user ID needed to access the node.
Password—Enter the password for the user ID.
Upload Package—Check this box to send the software package file to the node. If unchecked, the
software stored on the node is not modified.
Force Upload—Check this box to send the software package file to the node even if the node is
running the same software version. If unchecked, reinitialization will not send the software package
if the node is already running the same version.
Activate/Revert—Check this box to activate the uploaded software (if the software version is later
than the one installed) or revert to the uploaded software (if the software version is earlier than the
one installed) as soon as the software file is uploaded. If unchecked, the software is not activated or
reverted after the upload, allowing you to initiate the functions later from the node view
Maintenance > Software tab.
Re-init Database—Check this box to send a new database to the node. (This is equivalent to the CTC
database restore operation.) If unchecked, the node database is not modified.
Confirm—Check this box if you want a warning message displayed before any operation is
performed. If unchecked, reinitialization does not display a warning message.
Search Path—Enter the path to the CISCO15454SDH folder on the CD drive.
Purpose This task reinitializes the ONS 15454 SDH using the CTC
reinitialization (reinit) tool on a UNIX computer. Reinitialization
uploads a new software package to the TCC2/TCC2P cards, clears the
node database, and restores the factory default parameters.
Tools/Equipment ONS 15454 SDH System Software CD, Version 7.2
JRE 1.4.2 or JRE 5.0 must be installed on the computer to log into the
node at the completion of the reinitialization. The reinitialization tool
can run on JRE 1.3.1_02, JRE 1.4.2, or JRE 5.0.
Prerequisite Procedures DLP-D60 Log into CTC, page 17-49
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Superuser