DLP- D263 Edit SNCP Dual-Ring Interconnect Circuit Hold-Off Timer
Step 5 Click OK. Circuits matching the attributes in the Filter Circuits dialog box appear in the Circuits
window.
Step 6 To turn filtering off, click the Filter icon in the lower right corner of the Circuits window. Click the icon
again to turn filtering on, and click the Filter button to change the filter attributes.
Step 7 Return to your originating procedure (NTP).
DLP-D263 Edit SNCP Dual-Ring Interconnect Circuit Hold-Off Timer
Step 1 From the View menu, choose Go to Network View.
Step 2 Click the Circuits tab.
Step 3 Click the SNCP circuit you want to edit, then click Edit.
Step 4 In the Edit Circuit window, click the SNCP Selectors tab.
Step 5 In the Hold-off Timer column, double-click the cell of the circuit span you want to edit, then type the
new hold-off time. The range is 0 to 10,000 ms in increments of 100.
Step 6 Repeat Step 5, as needed, to adjust the hold-off timer for each circuit span.
Step 7 Click Apply, then close the Edit Circuit window by choosing Close from the File menu.
Step 8 Return to your originating procedure (NTP).
Purpose This task changes the amount of time a path selector switch is delayed for
circuits routed on an SNCP dual-ring interconnect (DRI) topology. In
DRIs, switching contention might occur depending upon the relative
switching speed of the path selector and the transmission delay on the
alternative routes. The hold-off time (HOT) allows you to change switch
times to prevent the switching contention.
Tools/Equipment None
Prerequisite Procedures NTP-D44 Provision SNCP Nodes, page 5-22
DLP-D60 Log into CTC, page 17-49
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Provisioning or higher