Cisco Systems OL-20932-02 Network Router User Manual


 
1-6
Cisco Physical Access Gateway User Guide
OL-20932-02
Chapter 1 Overview
Optional Expansion Modules
Module Features
Figure 1-4 shows the modules for a Cisco Physical Access Control system.
Figure 1-4 Cisco Physical Access Gateway and the Optional Modules
Gateway Cisco Reader Module Cisco Input Module Cisco Output Module
Mandatory module.
Connects up to two doors
using the 10 pin Wiegand
reader port, which can be
configured as two
five-pin ports.
Connects up to 15
optional expansion
modules using a
three-wire CAN bus.
1
Power-over-Ethernet
(POE) or 12 through 24V
DC
Two Ethernet ports
Three output ports:
Form C contacts rated at
5A 30VDC
Three supervised input
ports
2
Tamper & Power Fail
inputs (can be configured
as additional
unsupervised inputs)
One RS-485 serial port
(not supported in this
release).
1. The modules are connected using the CAN1 interface. The CAN2 interface is not supported in this release.
2. A supervised input supports four states: normal, alarm, open and short. An unsupervised input only indicates normal or alarm.
Requires connection to
an Access Gateway using
a three-wire CAN bus.
Connects up to two doors
using the 10 pin Wiegand
reader port, which can be
configured as two 5 pin
ports.
Power: 12 through 24V
DC
Three output ports: Form
C contacts rated at 5A
30VDC
Three supervised input
ports
Tamper & Power Fail
inputs (can be configured
as additional
unsupervised inputs)
One RS-485 serial port
(not supported in this
release).
Requires connection to
an Access Gateway using
a three-wire CAN bus.
10 supervised input ports
Example inputs are: Push
button switches, Glass
Break sensors, or any
contact closure input.
circuit
Power: 12 through 24V
DC
Tamper & Power Fail
inputs (can be configured
as additional
unsupervised ports)
Requires connection to
an Access Gateway using
a three-wire CAN bus.
8 output ports: Form C
contacts rated at 5A
30VDC
Example outputs are:
lights, LEDs, or any
contact closure output
circuit.
Power: 12 through 24V
DC
Tamper & Power Fail
inputs (can be configured
as additional
unsupervised ports)
Cisco Physical
Access Gateway
Reader
Module
Input
Module
Output
Module
187057