Cisco Systems OL-20932-02 Network Router User Manual


 
3-6
Cisco Physical Access Gateway User Guide
OL-20932-02
Chapter 3 Connecting a Cisco Reader Module
Installing the Cisco Reader Module
Status LEDs
Table 3-1 describes the Gateway module status LEDs:
Installing the Cisco Reader Module
Installing the Cisco Reader Module is similar to installing the Gateway, except for the following:
There are no Ethernet ports. The Cisco Reader Module is not directly connected to the IP network,
and is not directly configured.
The Cisco Reader Module does not support Power over Ethernet (PoE). The device is connected to
a DC power source.
The Cisco Reader Module must be terminated if it is the last device in a CAN wiring bus. See the
“CAN Bus Connections for Optional Modules” section on page 1-7 for more information.
Before You Begin
Before you install a Cisco Reader Module, verify the following:
Verify that the module has access to a power source. See the “Power Options and Requirements”
section on page 1-12 for more information.
Verify that you have the necessary mounting brackets or other hardware. See the “Mounting a
Gateway or Optional Module” section on page 1-14.
Procedure
To install the Cisco Reader Module, perform the following procedure:
Step 1 Mount the module to a wall. See the “Mounting a Gateway or Optional Module” section on page 1-14
for more information.
Step 2 Connect the module to the DC power source:
a. Insert a two-pin connector plug into the DC power port (Figure 3-5)
b. Connect the Voltage In (VIN) and ground (GND) wires.
Table 3-1 Gateway LEDs
Status Description
Input Port LEDs
OFF Input is not configured
GREEN Input is configured and in normal state
BLINKING GREEN Input is configured, and is receiving and alarm or other data.
BLINKING RED Input is configured, short
RED Input is configured, open
Output Port LEDs
Off Output not configured
Solid Green Output configured and in default state
Blinking Green Output configured and active