Dell 56F Switch User Manual


 
3-6 Installation and Troubleshooting Guide
'
Table 3-4 shows the front panel commands and their equivalent Te l n e t command.
$('!!'
 %& $ 
Configuration Ethernet IP Address ipAddrSet 10.1.2.3
Ethernet Subnetmask ipAddrSet None
Fibre Channel IP Address None
Fibre Channel Subnetmask None
Gateway Address None
Domain configure 0
R_A_TOV configure 16 (G_Port) -
0 (FL_Port)
E_D_TOV configure 10,000
Operating Mode configure 2000
Non-SCSI Tachyon Mode configure 0
Isolated Operation configure 0
Disable Device Probing configure 0
VC-Encoded Address
Mode
configure 0
Disable Translative Mode configure 0
Per-Frame Route Priority configure 0
VC Link Ctl configure 2
VC Class 2 configure 3
VC Class 3 configure 7
VC Multicast configure 0,1,2,2,2,2,3,3
Frame Collection configure Pilling
Reset to Default configDefault N/A
Operation Switch Offline switchDisable N/A
Switch Online switchEnable N/A
Port Disable portDisable <
port#
>N/A
Port Enable portEnable <
port#
>N/A
Close
Te l n e t
Session logout N/A
Reboot reboot N/A
Status Switch Name switchShow N/A