Dell 56F Switch User Manual


 
support.dell.com PowerVault 56F 16-Port Fibre Channel Switch Commands 4-31
)%
The
syslogdIp
command sets or displays the switches system log daemon IP
address. The command syntax is
syslogdip <ip address>.
%#
The following example shows the
tempShow
command screen, which shows the
switchs temperature as measured by five sensors on the system board.
Port state
The port state follows the GBIC type; the possible port states
include:
No_Card
No card present in this switch slot
No_Module
No GBIC module in this port
No_Light
The module is not receiving light
No_Sync
The module is receiving light but is out of
sync
In_Sync
The module is receiving light and is in sync
Laser_Flt
The module is signaling a laser fault (defec-
tive GBIC)
Port_Flt
The port has been marked faulty (defective
GBIC, cable, or device)
Diag_Flt
The port failed diagnostics (defective G_Port
or FL_Port card or system board)
Online
The port is up and running
Lock_Ref
The port locking to the reference signal
Te s t i n g
Running diagnostics
Comment field
The comment field follows the port state. The possible com-
ments include:
Disabled
The port is disabled
Loopback
The port is in loopback mode
E_Port
The WWN and switch name of the other
switch is shown, the use of this Inter Switch Link (ISL) is
shown (see FC_SW)
F_Port
The WWN of the N_Port is shown
G_Port
The port is online but is not yet an E_Port or
F_Port
L_Port
The port is connected to an arbitrated loop
(/!!''
% 