Dell 56F Switch User Manual


 
support.dell.com Managing the PowerVault 56F 16-Port Fibre Channel Switch 3-21
The configurable parameters include the following:
SNMPv1 communities (up to 6)
Trap recipients (1 per community)
sysName
sysContact
sysLocation
authenticationFailure Indicates the manage node has received a protocol mes-
sage that is not properly authenticated. This trap, by default, is disabled but can
be enabled by way of the

command.
swEventTrapLevel Indicates the swEventTrap severity level in conjunction with
an event's severity level. When an event occurs and if its severity level is at or
below the set value, the SNMP trap, swEventTrap, is sent to configured recipi-
ents. By default, this value is set at
0
, implying that no swEventTrap is sent.
Possible values are as follows:
0
None
1
Critical
2
Error
3
Warning
4
Informational
5
Debug
See Appendix A, Error Messages, for more information.
These parameters can be changed by way of the
Te l n e t
command, the
agtcfgset
command or by way of SNMP.
The sysX parameters can be configured by way of the

command with
an appropriate community. These parameters can be configured by way of a
Te l n e t
connection, using the

command.
NOTE: A change in the first two configuration parameters takes effect
only
after
rebooting the switch.
"
The FCP inquiry data obtained by device probing may now be obtained from the
Name Server by retrieving the port symbolic name.