Dell 56F Switch User Manual


 
support.dell.com PowerVault 56F 16-Port Fibre Channel Switch Commands 4-41
The following is an example of the
topologyShow
command screen.
'
The
uRouteConfig
command allows you to select the destination traffics path on a
source-port basis, as shown in the following screen example:
48'/'"4B85B485B''8
After using this command, traffic coming in from the port addressed to a domain is
forwarded through the output port. Make sure that the output port is a viable path for
reaching the domain.
The port can be an E_Port or an F_Port. If it is an E_Port, make sure that no routing
loops are created.
If the output port is not an E_Port, the route is allocated dynamically to a different
path, if one is available, as if this was a regular route. If the output port goes down,
the route is treated as a regular route and is allocated to a different path, again, if one
is available. When the output port comes back up, the port is rerouted back to the
static route.
Load sharing continues, taking into account static routes when counting the number
of routes that are allocated to a path, acting only on regular, non-static routes.
If port has a static route, the
flags
field in
uRouteShow
is set to
S
instead of
D
. Note
that this does not affect the
flags
field in the
topologyShow
command. The latter still
shows
D
unless a static path is configured.
The following example shows the
uRouteConfig
command screen:
648'/'"4!5!5
44'44

The
uRouteRemove
command removes the previous static route configuration, as
shown in the following example:
648'/'/B9%/$85B3%018
648#6
23413-
34 D%'9149)

 ! ! ! +3 G4 G
!  +!3
!  + 3