Dell HX574 Server User Manual


 
148 Troubleshooting Your System
Troubleshooting Serial I/O Problems
Problem
Error message indicates a problem with a serial port.
Device connected to a serial port is not operating properly.
Action
1
Enter the System Setup program and ensure that the serial port is enabled
and configured correctly for your application. See "Using the System Setup
Program" on page 43.
2
If the problem is confined to a particular application, see the application
documentation for specific port configuration requirements that the
program may require.
3
Run the appropriate online diagnostic test. See "Using Dell PowerEdge
Diagnostics" on page 167.
If the tests run successfully but the problem persists, see Troubleshooting a
Serial I/O Device.
Troubleshooting a Serial I/O Device
Problem
Device connected to the serial port is not operating properly.
Action
1
Turn off the system and any peripheral devices connected to the serial
port.
2
Swap the serial interface cable with a working cable, and turn on the
system and the serial device.
If the problem is resolved, replace the interface cable.
3
Turn off the system and the serial device, and swap the device with a
comparable device.