Dell HX574 Server User Manual


 
28 About Your System
E1812 HDD ##
Removed
Specified hard drive has
been removed from the
system.
Information only.
E1914 DRAC5 Conn2
Cbl
DRAC 5 cable is missing
or unseated.
Reconnect the cable. See
"RAC Card" on page 83.
E1A14 SAS Cable A SAS cable A is unseated,
missing, or bad.
Check the cable
connection to the SAS
backplane. See "SAS
Backplane Board
Connectors" on page 176.
E1A15 SAS Cable B SAS cable B is unseated,
missing, or bad.
Check the cable
connection to the SAS
backplane. See "SAS
Backplane Board
Connectors" on page 176.
E1A1C LOM Mezz
Missing
NIC daughter card is
missing.
Install or reseat the NIC
daughter card.
E2010 No Memory No memory is installed in
the system.
Install memory modules.
See "System Memory" on
page 91.
E2011 Mem Config
Err
Memory detected, but is
not configurable. Error
detected during memory
configuration.
Check the memory
configuration and
reinstall the memory
modules if necessary. See
"System Memory" on
page 91.
See "Troubleshooting
System Memory" on
page 156.
E2012 Unusable
Memory
Memory is configured,
but not usable. Memory
subsystem failure.
See "Troubleshooting
System Memory" on
page 156.
Table 1-7. LCD Status Messages (continued)
Line 1
Message
Line 2
Message
Causes Corrective Actions