Dell HX574 Server User Manual


 
About Your System 39
Read fault
Requested sector
not found
The operating system
cannot read from the hard
drive, the system could
not find a particular
sector on the disk, or the
requested sector is
defective.
Replace the diskette.
Ensure that the diskette
and hard drive cables are
properly connected. See
"Troubleshooting an
Optical Drive" on page 158,
or "Troubleshooting a Hard
Drive" on page 159 for the
appropriate drive(s)
installed in your system.
Remote Access
Controller cable
error or incorrect
card in the RAC
slot.
RAC cables are not
connected, or RAC card is
installed in the wrong
expansion slot.
Check that the RAC cables
are connected, and that the
RAC card is installed in the
correct expansion slot. See
"RAC Card" on page 83.
Remote Access
Controller not
installed in the
RAC slot.
RAC card is installed in
the wrong expansion slot.
Check that the RAC card is
installed in the correct
expansion slot. See "RAC
Card" on page 83.
Remote
configuration
update attempt
failed
System unable to process
Remote Configuration
request.
Retry Remote
Configuration.
ROM bad checksum =
address
An expansion card is
improperly installed or is
faulty.
Reseat the expansion cards.
Ensure that all appropriate
cables are securely
connected to the expansion
cards. If the problem
persists, see
"Troubleshooting
Expansion Cards" on
page 164.
Sector not found
Seek error
Seek operation
failed
Faulty hard drive. See "Troubleshooting a
Hard Drive" on page 159.
Table 1-8. System Messages (continued)
Message Causes Corrective Actions