Dell HX574 Server User Manual


 
22 About Your System
Table 1-7. LCD Status Messages
Line 1
Message
Line 2
Message
Causes Corrective Actions
N/A
SYSTEM NAME
A 62-character string that
can be defined by the user
in the System Setup
program.
The
SYSTEM NAME
displays under the
following conditions:
The system is powered
on.
The power is off and
active POST errors are
displayed.
This message is for
information only.
You can change the
system string in the
System Setup program.
See "Using the System
Setup Program" on
page 43.
E1000 FAILSAFE,
Call Support
See "Getting Help" on
page 179.
E1114 Temp Ambient Ambient system
temperature is out of
acceptable range.
See "Troubleshooting
System Cooling
Problems" on page 155.
E1210 CMOS Batt CMOS battery is missing,
or the voltage is out of
acceptable range.
See "Troubleshooting the
System Battery" on
page 153.
E1211 ROMB Batt RAID battery is either
missing, bad, or unable to
recharge due to thermal
issues.
Reseat the RAID battery.
See "Installing the SAS
RAID Controller Card
Battery" on page 113, and
"Troubleshooting System
Cooling Problems" on
page 155.
E12
nn #
PwrGd Specified voltage
regulator has failed.
See "Getting Help" on
page 179.
E1229 CPU # VCORE Processor # VCORE
voltage regulator has
failed.
See "Getting Help" on
page 179.