CONFIDENTIAL
Paper roll Miscellaneous commands DLE DC4 (fn = 2)
Ver. 10.01 p. 385
DLE DC4 (fn = 2)
EXECUTING COMMAND
[Name] Execute power-off sequence
[Format] ASCII DLE DC4
fn a b
Hex 10 14
02 a b
Decimal 16 20
2ab
[Printers not featuring this command] TM-T88III, TM-L60II, TM-U230, TM-U220, TM-U210, TM-U300A/B
[Range]
fn
= 2
a
= 1
b
= 8
[Description] Executes the printer power-off sequence and transmits the power-off notice.
• Saving the maintenance counter values
• Busy controlling for interface
• Changing to waiting state of mechanism
Executes power off processing (this processing depends on printer model).
[Notes]
■ This is a real-time command that the printer executes upon receiving it. Note the following when using
this command.
• If this command is embedded within the code string of another command, it is processed as a
parameter of the other command, and the print result is not correct.
• If another command (such as graphics data or defined data) has a code string in a parameter that is the
same as this command, the printer starts processing this command.
■ This command is ignored in the following states:
• During transmission of block data (Header ~ NUL)
• When this command is disabled by GS (D
■ With a serial interface, the printer executes this command even when it is in offline, receive buffer full, or
error status.
Miscellaneous commands