Epson TM-T88III Printer User Manual


 
CONFIDENTIAL
Paper roll Customize commands GS ( M
Ver. 10.01 p. 633
GS ( M pL pH fn m <Function 3>
[Name] Select the setting values loaded to the work area after the initialization process
[Format] ASCII GS ( M
pL pH fn m
Hex 1D 28 4D
02 00 fn m
Decimal 294077
2 0fnm
[Range] (
pL
+
pH
× 256) = 2, (
pL
= 2,
pH
= 0),
fn
= 3, 51
TM-J2000/J2100, TM-T90, TM-L90, TM-P60:
m
= 0,1, 48, 49
[Default]
m
= 0
[Description] Selects the command setting values loaded to the work area after the printer performs the initialization
process.
When
m
= 0, 48, the default values described in this guide are applied.
When
m
0, 48, the setting values are stored in the storage area specified by
m
.
[Notes]
This function does not change the values in the work area and storage area.
The setting of this function affects the following initializations.
Turning on the power.
Resetting the hardware by using a reset terminal.
Executing ESC @.
Executing a software reset.
The specification of this function is maintained after turning off the power.
In autoload processing, the values of the commands that are in the work area and are not affected by this
function and the values in the storage area are not changed.
The values affected by autoload processing of this function are different, depending on the printer
models. See model-dependent variations for details.