CONFIDENTIAL
Paper roll Customize commands GS ( E
Ver. 10.01 p. 611
• If the communication control between host and printer does not correspond, the printer cannot
process data from the host normally, and the host cannot receive data from the printer normally.
■ This function works in user setting mode.
■ This function works with serial interface printers.
■ The communication condition set by this function is enabled by executing Function 2 or restarting the
printer. It is necessary to change the communication condition of the host to be the same as the printer to
communicate with the printer.
■ To enable the communication condition set by this function, select “by memory switch” in the DIP switch
settings (Interface condition selection).
■ Communication conditions set are valid until the following operations are executed. They are not
initialized by power off or ESC @.
• Execution of this function.
• Execution of memory switch setting mode by panel operation when the power is turned on (supported
by some printer models.)
[Model-dependent variations] TM-J2000/J2100, TM-T90, TM-L90, TM-P60, TM-U220
TM-J2000/J2100
DIP switch for setting communication condition is Sw 2. When DIP switch is off, this function is
enabled. 7 baud rates are selectable.
[“2400 “,“4800 “, “9600 “, “19200 “, “38400 “, “57600 “, “115200 “]
Setting of this function can be changed by “Memory switch setting mode” by the panel switch
operation when the power supply is turned on.
TM-T90
DIP switch for setting communication condition is Sw 2. When DIP switch is off, this function is enabled. 7
baud rates are selectable.
[“2400 “,“4800 “, “9600 “, “19200 “, “38400 “, “57600 “, “115200 “]
Setting of this function can be changed by “Memory switch setting mode” by the panel switch operation
when the power supply is turned on.