CONFIDENTIAL
Paper roll Status commands DLE EOT
Ver. 10.01 p. 310
TM-L60II
When the printer is not selected ECS =, this command cannot be used.
BUSY condition for a serial interface is selected by DIP switch 2-1.
BUSY condition for a parallel interface is selected by DIP switch 1-3.
■ Printer status (
n
= 1)
Bits 5 and 6 of the printer status are undefined.
■ Error status (
n
= 3)
Bit 3 of the error status is undefined.
TM-P60
Use this command according to the following rule; otherwise, the status might not be
transmitted.
The next data is not transmitted until status is received when the command of the DLE EOT is
transmitted.
Only when it is necessary to acquire plural, real-time status items continuously, up to 4 DLE EOT
commands can be transmitted continuously. However, the next data is not transmitted until all
status is received in this case.
■ Printer status (
n
= 1)
Bit 2 status is as follows:
Bit 5 of the printer status is not supported.
■ Error cause status (
n
= 3)
n:
Bit Binary Hex Decimal Function
2 0 00 0 Does not go offline by low battery. ... how to use
this table
1 04 4 Offline by low battery.