Paper roll Customize commands GS ( E
Ver. 10.01 p. 618
The setting unit is 0.1 mm. The relationship between each setting value of the layout of the vertical
direction and paper layout is as follows.
[Notes]
This function works in user setting mode.
The origin of layout can be specified by
sa
as follows.
When Type B paper specified by
sa
= 49 is used or
sa
= 64, notice the setting of print area and cutting
position as follows.
Specify
sd, sf, sg, sh
so that the print area is on a label area. Don’t specify print area on the liner
(backing paper).
Specify
se
so that the cutting position is on the liner (backing paper). Don’t specify the cutting position
on a label area.
Specify
sa ~ sh
are converted to character codes corresponding to decimal data, then transmitted from
the MSB. (Example: When specifying 120, data is “120” (in decimal: 49, 50, 48; it is 3 byte).)
When you don’t change the origin of layout that is specified,
sa
can be omitted. However, “;“cannot be
omitted even if the parameter is omitted.
Example (
sa
is omitted): GS(E
pL
pH fn ; sb ; sc ; sd ; se ; sf ; sg ; sh ;